Defined interface
Available interfaces can be selected around the OCP Universal Quick Disconnect specification. Interchangeability applies only between plug and socket parts that meet the same UQD requirements and nominal size.
04 / Applications
Liquid cooling components for high-density AI compute infrastructure
AI Data Center Liquid Cooling
As AI clusters and next-generation GPUs increase rack power density, liquid cooling is becoming part of the critical data center infrastructure. Vantimond provides quick disconnect and stainless steel circulation pump platforms for CDU, manifold, rack, and server-loop integration.
Connector interfaces, coolant compatibility, allowable pressure loss, flow demand, redundancy, and acceptance testing are confirmed against the selected system architecture. OCP or platform-specific compliance is stated only where the supplied model documentation demonstrates it.
Product Lineup 01
High-precision dry-break fluid connectors for server, rack manifold, and cooling distribution integration.
Available interfaces can be selected around the OCP Universal Quick Disconnect specification. Interchangeability applies only between plug and socket parts that meet the same UQD requirements and nominal size.
Flush-face dry-break architecture is intended to limit coolant release during service. Allowable spillage, leakage rate, pressure, temperature, fluid, and cycle life must be confirmed in the approved product data.
Connector selection considers flow coefficient and pressure loss so the cooling loop can meet its hydraulic duty without unnecessary pumping overhead.
Interface names and dimensions follow the published OCP UQD Rev 1.0 specification. Final Vantimond model compliance, Cv, spillage, leakage, pressure, temperature, fluid compatibility, and lifecycle data require the issued datasheet or test report.
Review connector construction, interface sizes, and the technical selection framework.
Explore UQD SeriesProduct Lineup 02
Continuous circulation platforms for dynamic thermal management in high-density AI clusters.

For primary CDU circulation loops, facility cooling infrastructure, and higher-flow process water duties. Stainless steel 304 or 316L wetted configurations are selected around coolant chemistry and project requirements.
Hermetically sealed, seal-less pump architecture for rack-level CDUs and duties where containment, compact installation, low noise, and variable-speed control are priorities.
Review the complete SSP application range and project-specific selection notes.
Explore stainless steel pumpsStart with the cooling architecture