AI Data Centers

Liquid cooling components for high-density AI compute infrastructure

AI Data Center Liquid Cooling

Powering next-generation AI compute infrastructure with controlled, serviceable fluid connections

As AI clusters and next-generation GPUs increase rack power density, liquid cooling is becoming part of the critical data center infrastructure. Vantimond provides quick disconnect and stainless steel circulation pump platforms for CDU, manifold, rack, and server-loop integration.

Connector interfaces, coolant compatibility, allowable pressure loss, flow demand, redundancy, and acceptance testing are confirmed against the selected system architecture. OCP or platform-specific compliance is stated only where the supplied model documentation demonstrates it.

Stainless steel liquid cooling manifolds and serviceable quick disconnects beside AI server racks

Product Lineup 01

Universal Quick Disconnects

High-precision dry-break fluid connectors for server, rack manifold, and cooling distribution integration.

Defined interface

Available interfaces can be selected around the OCP Universal Quick Disconnect specification. Interchangeability applies only between plug and socket parts that meet the same UQD requirements and nominal size.

Controlled fluid separation

Flush-face dry-break architecture is intended to limit coolant release during service. Allowable spillage, leakage rate, pressure, temperature, fluid, and cycle life must be confirmed in the approved product data.

Hydraulic efficiency

Connector selection considers flow coefficient and pressure loss so the cooling loop can meet its hydraulic duty without unnecessary pumping overhead.

ModelOCP nominal interfaceTypical integration point
UQD021/8 inCompact equipment and internal fluid-loop connections
UQD041/4 inServer and cold-plate loop connections
UQD063/8 inHigher-flow equipment and manifold branches
UQD081/2 inRack and distribution manifold integration

Interface names and dimensions follow the published OCP UQD Rev 1.0 specification. Final Vantimond model compliance, Cv, spillage, leakage, pressure, temperature, fluid compatibility, and lifecycle data require the issued datasheet or test report.

Review connector construction, interface sizes, and the technical selection framework.

Explore UQD Series

Product Lineup 02

High-purity stainless steel pumps

Continuous circulation platforms for dynamic thermal management in high-density AI clusters.

Horizontal and vertical stainless steel multistage pumps in an industrial liquid cooling test bay
SSP-C Series

Horizontal and vertical multistage centrifugal pumps

For primary CDU circulation loops, facility cooling infrastructure, and higher-flow process water duties. Stainless steel 304 or 316L wetted configurations are selected around coolant chemistry and project requirements.

Flow
Up to 240 m³/h
Head
Up to 305 m
SSP-M Series

Permanent magnet canned motor pumps

Hermetically sealed, seal-less pump architecture for rack-level CDUs and duties where containment, compact installation, low noise, and variable-speed control are priorities.

Control
VFD / inverter compatible by selected motor and drive package
Selection
Confirm flow, head, fluid, temperature, power, and redundancy

Review the complete SSP application range and project-specific selection notes.

Explore stainless steel pumps

Start with the cooling architecture

Share the connector interface and hydraulic duty

Request engineering review